5.8

Precautions for Storing and Handling Supplies

5.8.1
Precautions for storing TOSHIBA supplies
1. Toner/Developer
Toner and developer should be stored in a place where the ambient temperature is between 10°C to
35°C (no condensation), and should also be protected against direct sunlight during transportation.
2. Photoconductive drum
Like the toner and developer, photoconductive drum should be stored in a dark place where the
ambient temperature is between 10°C to 35°C (no condensation). Be sure to avoid places where
drums may be subjected to high humidity, chemicals and/or their fumes.
3. Drum cleaning blade
This item should be stored in a flat place where the ambient temperature is between 10°C to 35°C,
and should also be protected against high humidity, chemicals and/or their fumes.
4. Fuser roller / Pressure roller
Avoid places where the rollers may be subjected to high humidity, chemicals and/or their fumes.
5. Paper
Avoid storing paper in places where it may be subjected to high humidity. After a package is opened,
be sure to place and store it in a storage bag.
6. Transfer roller
Transfer roller should be stored in a place where the ambient temperature is between 10°C to 35°C
(no condensation). Be sure to avoid places where transfer roller may be subjected to high humidity,
chemicals and/or their fumes.