CHAPTER 17 SERIAL INTERFACE CHANNEL 0 ( PD78054Y Subseries)
17.4.5 Cautions on use of I
(1) Start condition output (master)
The SCL pin normally outputs a low-level signal when no serial clock is output. It is necessary to change
the SCL pin to high in order to output a start condition signal. Set 1 in CLC of interrupt timing specify
register (SINT) to drive the SCL pin high.
After setting CLC, clear CLC to 0 and return the SCL pin to low. If CLC remains 1, no serial clock is output.
If it is the master device which outputs the start condition and stop condition signals, confirm that CLD is set
to 1 after setting CLC to 1; a slave device may have set SCL to low (wait state).
SDA0(SDA1)
2
C bus mode
Figure 17-24. Start Condition Output
SCL
CLC
CMDT
CLD
385