APPENDIX B CAUTIONS ON DESIGNING TARGET SYSTEM
Figures B-1 and B-2 show the conditions when connecting the emulation probe to the conversion connector.
Follow the configuration below and consider the shape of parts to be mounted on the target system when designing a
system.
SWEX-144SD-1, NQPACK144SD, and YQPACK144SD described in this appendix are products of TOKYO
ELETECH CORPORATION.
Figure B-1. Distance Between In-Circuit Emulator and Conversion Connector
In-circuit emulator
IE-78K0-NS or IE-78K0-NS-A
Emulation board
IE-789835-NS-EM1
CN2 CN3
CN1
Emulation board
IE-789835-NS-EM1
Conversion
connector
NQPACK144SD+
YQPACK144SD
335 ±8 mm
Emulation probe
SWEX-144SD-1
FG Cable
(Supplied)
Figure B-2. Connection to Target System
Emulation probe
SWEX-144SD-1
29 mm
55.5 mm
User's Manual U16290EJ1V0UM
Target system
Conversion connector
NQPACK144SD +
YQPACK144SD
18.5 mm
29 mm
47.5 mm
Target system
43