NEC PD78052 User Manual page 374

Pd78054 series; pd78054y series 8-bit single-chip microcontrollers
Table of Contents

Advertisement

CHAPTER 17 SERIAL INTERFACE CHANNEL 0 ( PD78054Y Subseries)
R/W
ACKE
Acknowledge Signal Automatic Output Control
0
Disabled (with ACKT enabled). Used when receiving data in the 8-clock wait mode or when transmitting
Note 2
data.
1
Enabled.
After completion of transfer, acknowledge signal is output in synchronization with the 9th falling edge of
SCL clock (automatically output when ACKE = 1). However, not automatically cleared to 0 after
acknowledge signal output. Used for reception when the 9-clock wait mode is selected.
R
ACKD
Acknowledge Detection
0
Clear Conditions
• When transfer start instruction is executed
• When CSIE0 = 0
• When RESET input is applied
1
Set Conditions
• When acknowledge signal is detected at the rising edge of SCL clock after completion of transfer
R/W
BSYE
Control of N-ch Open-Drain Output for Transmission in I
Note 3
0
Output enabled (transmission)
1
Output disabled (reception)
Notes 1. This setting must be performed prior to transfer start.
2. In the 8-clock wait mode, use ACKT for output of the acknowledge signal after normal data reception.
3. The busy mode can be released by the start of a serial interface transfer or reception of an address
signal. However, the BSYE flag is not cleared.
4. When using the wake-up function, be sure to set BSYE to 1.
Remark
CSIE0: Bit 7 of serial operating mode register 0 (CSIM0)
374
Note 1
2
Note 4
C Bus Mode