Ricoh D146 Service Manual page 1357

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables-6
2.8 MAIN SP TABLES-6
2.8.1 SP6-XXX (PERIPHERALS)
6006
[ADF Adjustment]
Side-to-Side Regist: Front
001
Adjusts front side main scan register for ADF.
Side-to-Side Regist: Rear
002
Adjusts rear side main scan register for ADF.
Leading Edge Registration
Adjusts DFGATE assert timing.
003
§
Value increase: Delays DFGATE assert timing.
§
Value decrease: Delays DFGATE assert timing.
Buckle: Duplex Front
Adjusts front side buckle amount (skew correct amount).
005
§
Value increase: increases front side buckle amount.
§
Value decrease: decreases front side buckle amount.
Buckle: Duplex Rear
Adjusts rear side buckle amount (skew correct amount).
006
§
Value increase: increases rear side buckle amount.
§
Value decrease: decreases rear side buckle amount.
Rear Edge Erase
Adjusts DFGATE negate timing.
007
§
Value increase: Delays DFGATE negate timing.
§
Value decrease: Delays DFGATE negate timing. (Direction for erasing
trailing edge of original)
D146/D147/D148/D149/D150
*ENG
[-3.0 to 3.0 / 0.0 / 0.1 mm/step]
*ENG
[-3.0 to 3.0 / 0.0 / 0.1 mm/step]
*ENG
[-5.0 to 5.0 / 0.0 / 0.1 mm/step]
*ENG
[-5.0 to 5.0 / 0.0 / 0.1 mm/step]
*ENG
[-5.0 to 5.0 / 0.0 / 0.1 mm/step]
*ENG
[-10.0 to 10.0 / 0.0 / 0.1 mm/step]
2-638