Ricoh D146 Service Manual page 1826

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Code
0-08
The other end sent RTN or
PIN after receiving a page,
because there were too many
errors
0-14
Non-standard post message
response code received
0-15
The other terminal is not
capable of specific functions.
D163
Meaning
Suggested Cause/Action
Check the line connection.
Replace the FCU.
The other end may have jammed, or run
out of paper or memory space.
Try adjusting the tx level and/or cable
equalizer settings.
The other end may have a defective
modem/FCU; try sending to another
machine.
Check for line problems and noise.
Cross reference
Tx level - NCU Parameter 01 (PSTN)
Cable equalizer - G3 Switch 07 (PSTN)
Dedicated Tx parameters in Service
Program Mode
Incompatible or defective remote terminal;
try sending to another machine.
Noisy line: resend.
Try adjusting the tx level and/or cable
equalizer settings.
Replace the FCU.
Cross reference
See error code 0-08.
The other terminal is not capable of accepting
the following functions, or the other terminal's
memory is full.
Confidential rx
Transfer function
SEP/SUB/PWD/SID
50