4803
[Home Position Adj Value]
-
001
Run Home position operation (Homing).
4804
[Home Position Operation]
-
001
Run Home position operation (Homing).
4806
[Scan Carriage Retract Op]
-
001
Run Carriage retract operation.
4807
[SBU Off Mode]
On/Off
001
Switch ON/OFF for stopping CCD drive clock of SBU when scanner is standby.
Use for process adjustment/design evaluation.
System Maintenance Section
ENG
[-2 to 2 / 0 / 0.1mm/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
[0 or 1 / 1 / 0]
ENG
0:OFF
1:ON(default)
2-515
D146/D147/D148/D149/D150
Main SP Tables - 4