Ricoh D146 Service Manual page 1830

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Code
0-77
The called terminal fell back to
T.30 mode, because it could
not detect a CJ in response to
JM
(JM timeout).
0-79
The called terminal detected
CI while waiting for a V.21
signal.
0-80
The line was disconnected
due to a timeout in V.34 phase
2 – line probing.
0-81
The line was disconnected
due to a timeout in V.34 phase
3 – equalizer training.
0-82
The line was disconnected
due to a timeout in the V.34
phase 4 – control channel
start-up.
0-83
The line was disconnected
due to a timeout in the V.34
control channel restart
sequence.
0-84
The line was disconnected
due to abnormal signaling in
V.34 phase 4 – control
channel start-up.
D163
Meaning
Suggested Cause/Action
The calling terminal could not detect a JM
due to noise, etc.
A network that has narrow bandwidth
cannot pass JM to the other end.
Check the line connection and condition.
Try receiving a call from another V.8/V.34
fax.
Check for line noise or other line problems.
If this error occurs, the called terminal falls
back to T.30 mode.
The guard timer expired while starting
these phases. Serious noise, narrow
bandwidth, or low signal level can cause
these errors.
If these errors happen at the transmitting
terminal:
Try making a call at a later time.
Try using V.17 or a slower modem using
dedicated tx parameters.
Try increasing the tx level.
Try adjusting the tx cable equalizer setting.
If these errors happen at the receiving terminal:
Try adjusting the rx cable equalizer setting.
Try increasing the tx level.
Try using V.17 or a slower modem if the
same error is frequent when receiving from
multiple senders.
The signal did not stop within 10 s.
Turn off the main power switch, then turn it
back on.
If the same error is frequent, replace the
FCU.