Duplex Bypass
079
Motor:CCW:Low Speed
Duplex Bypass Motor: CCW:
080
Normal Speed: Feed
Duplex Bypass Motor: CCWr:
081
Low Speed: Feed
5804
[OUTPUT Check]
Duplex Bypass Motor:Position
Hold
083
Holds position of duplex bypass motor.
SI Bypass SF Drive Motor:CW
(500pps)
084
Moves SI bypass SF drive motor.
SI Bypass SF Dr
M:CW:PlsCnt:460Pls(2mm)
085
Moves SI bypass SF drive motor for 2mm.
SI Bypass SF Dr
M:CW:PlsCnt:920Pls(4mm)
086
Moves SI bypass SF drive motor for 4mm.
SI Bypass SF Drive
Motor:CCW (500pps)
087
Moves SI bypass SF drive motor.
SI Bypass SF Dr
M:CCW:PlsCnt:920Pls(2mm)
088
Moves SI bypass SF drive motor for 2mm.
SI Bypass SF Dr
M:CCW:PlsCnt:920Pls(4mm)
089
Moves SI bypass SF drive motor for 4mm.
System Maintenance Section
ENG
ENG
ENG
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
ENG
[0 or 1 / 0 / 1/step]
3-35
D146/D147/D148/D149/D150
Output Check Table