Ricoh D146 Service Manual page 1291

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables-5
5504
[Jam Alarm Interval]
-
001
Sets the alarm to sound for the specified jam level (document miss feeds are
not included).
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error
5505
alarm counter decreases by "1" when an SC is not detected during a set
number of copied sheets (for example, default 700 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 Error Alarm
[Supply/CC Alarm]
5507
Enables or disables the notifying a supply call via the @Remote.
001 Paper Supply Alarm
002 Staple Supply Alarm
Toner Supply Alarm
003
If you select "1" the alarm will sound when the copier detects toner end.
D146/D147/D148/D149/D150
[0 to 3 / 3 / 1/step]
0: Z
*CTL
1: L
2: M
3: H
[0 to 25500 / D146: 2500, D147:
3500, D148: 5000, D149: 6000,
*CTL
D150: 7500 /undred/step]
0: Alarm Off
[0 or 1 / 0 / 1/step]
*CTL
0: OFF
1: ON
[0 or 1 / 0 / 1/step]
*CTL
0: OFF
1: ON
[0 or 1 / 0 / 1/step]
*CTL
0: OFF
1: ON
2-572
System Maintenance Section

Hide quick links: