Main SP Tables-2-1
Page: Interrupt: FC
005
Condition threshold to auto execute MUSIC or not based on last printed sheets
from MUSIC during printing in Color mode.
Page: Stand-By: BW
006
Condition threshold to auto execute MUSIC or not based on last printed
B&W+Color sheets from MUSIC during stand-by.
Page: Stand-By: FC
007
Condition threshold to auto execute MUSIC or not based on last printed Color
sheets from MUSIC during stand-by.
Temp.
008
Condition threshold to auto execute MUSIC or not based on the variation of
environment temperature (Temperature and humidity sensor) since last MUSIC.
Time
009
Condition threshold to auto execute MUSIC on recover from energy save mode
/ Power on or not based on the elapsed time since last MUSIC.
010 Magnification
Temp. 2
Condition threshold (Threshold revel: Mid.) to auto execute MUSIC or not
011
based on the variation of internal temperature (drum temp. sensor) since last
MUSIC.
012 Time 2
Temp. 3
013
Condition threshold (Threshold revel: Hi.) to auto execute MUSIC or not based
on the variation of internal temperature (drum temp. sensor) since last MUSIC.
Page: Power ON:BW+FC
016
Condition threshold to auto execute MUSIC on recover from energy save mode
/ Power on or not based sheets printed during electrification.
D146/D147/D148/D149/D150
*ENG
[0 to 999 / 200 / 1page/step]
*ENG
[0 to 999 / 100 / 1page/step]
*ENG
[0 to 999 / 100 / 1page/step]
*ENG
[0 to 100 / 5 / 1deg/step]
*ENG
[1 to 1440 / 300 / 1minute/step]
*ENG
[0.00 to 1.00 / 0.10 / 0.01%/step]
*ENG
[0 to 100 / 5 / 1deg/step]
*ENG
[1 to 9999 / 600 / 1minute/step]
*ENG
[0 to 100 / 10 / 1deg/step]
*ENG
[0 to 999 / 200 / 1page/step]
2-194
System Maintenance Section