Ricoh D146 Service Manual page 875

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables-2-1
Relative Humidity Bk : Display
012
Relative temperature detected by the temperature / humidity sensor when
controlling Electrify AC of latest main & subs monochrome Bk mode.
Absolute Humidity Bk :
Display
013
Absolute temperature detected by the temperature / humidity sensor when
controlling Electrify AC of latest main & subs monochrome Bk mode.
2014
[Charge AC Control: Setting]
Exec Interval: Power ON
001
Page interval to do main control when Power ON, recover from energy save
mode, front door close.
Exec Interval: Print
002
Page interval to do main control when printing, finish printing.
Page Interval
003
Page interval to decide to adjust sub when printing in standard speed.
Temperature
004
Temperature threshold for sub control execute decision,
Relative Humidity
005
Threshold of relative humidity conditions to do sub adjustments.
Absolute Humidity
006
Threshold of absolute Temperature conditions to do sub adjustments.
D146/D147/D148/D149/D150
*ENG
[0 to 100 / 0 / 1%RH/step]
[0.00 to 100.00 / 0.00 /
*ENG
0.01g/m^3/step]
*ENG
[0 to 2000 / 500 / 1page/step]
*ENG
[0 to 2000 / 0 / 1page/step]
*ENG
[0 to 500 / 10 / 1page/step]
*ENG
[0 to 99 / 35 / 1deg/step]
*ENG
[0 to 99 / 50 / 1%RH/step]
*ENG
[0 to 99 / 12 / 1g/m^3/step]
2-156
System Maintenance Section

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents