Ricoh D146 Service Manual page 1317

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables-5
Confirm Place
205
Displays the installed section informed from G/W for response of request
number inquiry if the section is enrolled on the G/W.
Register Execute
206
Executes the registration of Cumin.
Register Result
207
Displays the registration result. Shows the executed status of SP5-816-206.
Error Code
208
Displays the registration result of SP5-816-204.
Invalid modem parameter
-11001
208
-11002
-11003
D146/D147/D148/D149/D150
Chat parameter error.
Chat execution error.
Unexpected error
[0 to 255 / 0 / 1/step]
0: Success registration
1: Request number error
3: Communication error (Enabled
Proxy)
4: Communication error (Disabled
Proxy)
5: Proxy error (failed auth.)
6: Communication error
CTL
8: Other error (See SP5-816-208
for detail)
9: Processing registration
20: Failed Dial-up auth.
21: Failed answer tone detection
22: Failed career detection
23: Invalid modem value
24: Shortage of electrical current
25: Cable disconnected
26: Line occupied
[- / - / -]
CTL
[Execute]
CTL
[0 to 255 / 0 / 1/step]
[-2147483647 to 2147483647 / 0 /
CTL
-]
2-598
System Maintenance Section

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents