Main SP Tables-2-1
2015
[Charge AC Adj: Result]
Bk
001
Result of AC adjust control for Bk (main / sub common)
C
002
Result of AC adjust control for C (main / sub common)
M
003
Result of AC adjust control for M (main / sub common)
Y
004
Result of AC adjust control for Y (main / sub common)
2020
[Background Pot Correction Set]
Temperature
001
Temperature threshold for calculating Electrify roller fatigue.
Absolute Humidity
002
Absolute humidity threshold for calculating Electrify roller fatigue.
Print Page Counter
003
Printing counter for multi-step correction.
Print Pages Threshold
004
Printing pages threshold when Multi-step correction.
Temp Thresh
005
Temperature threshold 2 for calculating Electrify roller fatigue.
Coefficient a: K
011
Coefficient a, K for calculating Electrify roller fatigue.
Coefficient a: C
012
Coefficient a, C for calculating Electrify roller fatigue.
D146/D147/D148/D149/D150
*ENG
[0 to 9 / 0 / 1/step]
*ENG
[0 to 9 / 0 / 1/step]
*ENG
[0 to 9 / 0 / 1/step]
*ENG
[0 to 9 / 0 / 1/step]
*ENG
[0 to 19 / 15 / 1deg/step]
*ENG
[0 to 99 / 6 / 1g/m^3/step]
*ENG
[0 to 999 / 0 / 1page/step]
*ENG
[0 to 999 / 10 / 1page/step]
*ENG
[20 to 99 / 20 / 1deg/step]
*ENG
[0.00 to 1.00 / 0.06 / 0.01/step]