Ricoh D146 Service Manual page 1109

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Main SP Tables-3
Displays latest value of ID sensor sensitivity correction coefficient: K7.
[ID.Sens Coef :Set]
3331
Assign (no need with Tomahawk) for having compatibility with unification model
sires (Ap/At, Diana, Zeus).
001 K2: Upp Limit Corr
002 K2: Lwr Limit Corr
003 K2: Upp/Lwr Limit Coef1
3331
[ID.Sens Coef :Set]
Kn: Upper
004
Sets upper limit valid range of standardization value for specular reflection used
for calculating sensitivity correction: K5.
Kn: Lower
005
Sets lower limit valid range of standardization value for specular reflection used
for calculating sensitivity correction: K5
K5: Upper
006
Sets upper limit value of calculated sensitivity correction coefficient: K5.
K5: Lower
007
Sets lower limit value of calculated sensitivity correction coefficient: K5.
K5: Target Point
008
Sets proofreading point (Kn) of sensitivity correction coefficient: K5.
K5: Target Voltage
009
Sets proofreading point (Kn) of sensitivity correction coefficient: K5.
Corrct Coef:C
012
Sets color diff correction coefficient (C) of Delta Vsp_Dif_Dash.
Corrct Coef:M
013
Sets color diff correction coefficient (M) of Delta Vsp_Dif_Dash.
D146/D147/D148/D149/D150
*ENG
[-0.20 to 0.40 / 0.17 / 0.01/step]
*ENG
[-0.40 to 0.20 / 0.03 / 0.01/step]
*ENG
[0.00 to 1.00 / 0.00 / 0. 01]
*ENG
[0.00 to 1.00 / 1.00 / 0.01/step]
*ENG
[0.00 to 1.00 / 0.10 / 0.01/step]
*ENG
[0.00 to 10.00 / 6.00 / 0.01/step]
*ENG
[0.00 to 1.00 / 0.50 / 0.01/step]
*ENG
[0.00 to 1.00 / 0.15 / 0.01/step]
*ENG
[0.00 to 5.00 / 1.63 / 0.01V/step]
*ENG
[0.500 to 1.500 / 1.000 / 0.001/step]
*ENG
[0.500 to 1.500 / 0.996 / 0.001/step]
2-390
System Maintenance Section

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150