Code
0-16
CFR or FTT not detected after
modem training in confidential
or transfer mode
0-17
Communication was
interrupted by pressing the
Stop key
0-20
Facsimile data not received
within 6 s of retraining
0-21
EOL signal (end-of-line) from
the other end not received
within 5 s of the previous EOL
signal
SM
Meaning
Suggested Cause/Action
Check the line connection.
Replace the FCU.
Try adjusting the tx level and/or cable
equalizer settings.
The other end may have disconnected, or
it may be defective; try calling another
machine.
If the rx signal level is too low, there may
be a line problem.
Cross reference
See error code 0-08.
If the Stop key was not pressed and this error
keeps occurring, replace the operation panel or
the operation panel drive board.
Check the line connection.
Replace the FCU.
Check for line problems.
Try calling another fax machine.
Try adjusting the reconstruction time for
the first line and/or rx cable equalizer
setting.
Cross reference
Reconstruction time - G3 Switch 0A, bit 6
Rx cable equalizer - G3 Switch 07 (PSTN)
Check the connections between the FCU
and line.
Check for line noise or other line problems.
Replace the FCU.
The remote machine may be defective or
may have disconnected.
Cross reference
Maximum interval between EOLs and between
ECM frames - G3 Bit Switch 0A, bit 4
51
D163

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150