Scanner SP Mode
1041
[Scanner FlairAPI Function Setting]
-
Sets Scanner FlairAPI Function enable / disable.
001
This SP is set by BitSwitch and needs to reboot the machine after making
changes.
bit
Setting
Start of FlairAPI
bit 0
Server
Access permission of
bit 1
FlairAPI from outside
of the machine
bit 2
Reserved
bit 3
Reserved
bit 4
Simple UI Function
D146/D147/D148/D149/D150
*CTL
* see BitSwitch below:
meanings
0
1
Off
On
(Do not
(Start)
Start)
Disabled
Enabled
-
-
-
-
Disabled
Enabled
2-816
Description
Sets whether to start
exclusive FlairAPI http
server. If it is 0, scanning
FlairAPI function and simple
UI function will be disabled.
The machine installed
Android operating panel
option, set "1", others set "0".
If it is "0", accessing is
limited from the machine
only, such as operating
panel, SDK/J, MFP browsers
etc... If it is "1", accessing is
allowed from outside of
FlairAPI such as PC,
Remote UI, IT-Box etc...
-
-
If it is "1", the machine can
be used Scanner Simple UI.
If it is "0", requesting URL of
Simple UI returns "404 Not
Found"
System Maintenance Section