Service Call 900-998
SC No.
Level
SC998-00
D
D146/D147/D148/D149/D150
Error Name/Error Condition/Major Cause/Solution
Application start error
§
No application was registered to system within a specified
time after the main power was turned on.
(No application starts/All applications have been terminated
abnormally)
§
Application started but cannot be drawn now for some
reason.
§
Software bug (mainly the application)
§
The optional RAM, DIMM, boards required by the
application program. Are not installed correctly.
§
Turn the main power off/on.
§
Check the optional RAM, DIMM, boards
§
Check the combination of programs
§
Replace the controller board.