[Extra Fan Control]
Extra Fan Cooling State
001
Displays current fan extend operation
002 Execution Temp. Threshold
Sets judge time for to start fan extend operation.
Cancellation Temp. Threshold
003
Sets temperature threshold (diff. value between fan extend start temp.) of when
ending fan extend operation.
Extra Fan Operation ON/OFF
Setting
004
Sets enable/disable fan extend operation.
1955
[Fan Control]
Dev Cooling Fan A Op Sw
Temp
003
Sets temperature threshold for when switching operation of imaging cooling fan
A.
Dev Cooling Fan B Op Sw
Temp
004
Sets temperature threshold for when switching operation of imaging cooling fan
B.
Paper Exit Cooling Fan Low
Temp Op Sw Temp
006
Sets temperature threshold for when switching operation during low temp. of
paper exit cooling fan.
System Maintenance Section
[0 or 1 / 0 / 1/step]
*ENG
0: Disable
1: Enable
[0.0 to 100.0 / D146:42.0,
*ENG
D147:42.0, D148:39.0, D149:39.0,
D150:39.0 / 0.1deg/step]
*ENG
[0.0 to 100.0 / 2.0 / 0.1deg/step]
[0 or 1 / 1 / 1/step]
*ENG
0: disable
1: enable
*ENG
[0.0 to 100.0 / 1.0 / 0.1deg/step]
*ENG
[0.0 to 100.0 / 36.0 / 0.1deg/step]
*ENG
[0.0 to 100.0 / 12.0 / 0.1deg/step]