Ricoh D146 Service Manual page 806

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Feed Permit
012
Temp.:delta:Press
013 Feed Permit Rotation Time
021 After Job End Temp.:Center
022 After Job End Temp.:End
023 After Job End Time
[Overshoot Prevent Control]
1157
Do not change. Over shoot prevent control.
Decision Time
001
Off sleep shift time
Decision Temp.
002
Judge temperature
-
003
Off sleep shift time
1161
[Shading Plate Control]
Judgment Temp A
001
Do not change. Temperature threshold of initial position judge
Judgment Temp B
002
Do not change. Temperature threshold of initial position judge
Position Transition Time
003
Do not change. Time from sensor temperature goes over threshold to position
shift fixed.
After Transition Time Out
004
Do not change. Time from after position shifted to next position shift judge.
System Maintenance Section
ENG
[0 to 200 / 100 / 1deg/step]
ENG
[0 to 100 / 0 / 1deg/step]
ENG
[0 to 200 / 5 / 1sec/step]
ENG
[0 to 200 / 5 / 1sec/step]
ENG
[0 to 100 / 0 / 1sec/step]
*ENG
[0 to 100 / 5 / 1sec/step]
[0 to 250 / D146:185, D147:185,
*ENG
D148:195, D149:200, D150:200 /
1deg/step]
*ENG
[0 to 300 / 15 / 1sec/step]
ENG
[0 to 250 / 250 / 1deg/step]
ENG
[0 to 250 / 250 / 1deg/step]
ENG
[0 to 10000 / 1000 / 1msec/step]
ENG
[0 to 20000 / 0 / 1msec/step]
2-87
Main SP Tables-1
D146/D147/D148/D149/D150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents