Configuring The Intellibus Device For A Rapid Eye Unit; To Configure An Acuix Dome Camera For Ptz Use; Table 6-3 Communications For The Intellibus Device, And For Each Acuix Dome Camera - Honeywell rapid eye System Administrator Manual

Multi-media
Hide thumbs Also See for rapid eye:
Table of Contents

Advertisement

Configuring the Intellibus Device for a Rapid Eye Unit

1.
Assign the Intellibus device to the port used by the installers, by dragging its icon from the
Unassigned Devices to a "Port n". Figure
Port "3" through "10". Select RS-485 on the Serial Devices tab.
Port "1" or "2". Select RS-232. Use a hardware converter for RS-232/RS-485 on these ports to
translate communications to and from the ACUIX dome cameras.
2.
On the Serial Devices tab, select the values shown in table 6–3. See also figure 6–14.
Fig. 6–14. Communication Settings for Intellibus on the Serial Devices Tab.
Table 6–3 Communications for the Intellibus Device, and for each ACUIX Dome Camera
Communications
Baud Rate
Stop Bits
Data Bits
Parity Bits

To Configure an ACUIX Dome Camera for PTZ Use

1.
Run a
Maintenance
2.
Click the Video tab.
3.
Click PTZ. For information about enabling and configuring a PTZ dome, see
PTZ, on p. 86.
4.
Select an ACUIX dome camera.
5.
In Port Attributes, enter values for Baud Rate, Stop Bits, Data Bits and Parity Bits, using those
shown in table 6–3.
Document 800-02325 Rev A
07/08
6–14
Value
38400
1
8
none
Session.
System Administrator Guide
shows the result when Port 4 is used.
Video Tab Settings for