* The values for IP addresses and ports depend on system administrator of the remote LAN.
† The Rapid Eye Multi Admin may need to indicate to the system administrator of the remote LAN
that the Maintenance and FTP values are increments of the Session value, in a connection.
See figure 3–12.
‡ All Rapid Eye units have the same port values, and these cannot be changed.
§ Each unit needs a unique IP Address.
Step 2: Match a Unit's Gateway to the Internet Router's Inside IP
Change a unit's IP onsite, using LocalView. Set the IP gateway on Rapid Eye unit to the internet
router's inside IP. To see a Rapid Eye unit's IP remotely: use View, run a
click the System tab.
Fig. 3–13. Unit IP for Network Connection Using NAT.
Note
Direct Connection to a Standalone PC
A standalone PC, running Admin and View software, is connected to one unit, using a network
crossover cable.
Document 800-02325 Rev A
07/08
Do not change a unit's IP address or IP gateway while operating a unit connected
using NAT; this "locks out" remote operators using that network connection to
the unit, until the change is mapped in the internet router.