Pan, Tilt, and Zoom (PTZ) Setup
2.
On the Serial Devices tab, click the port to which the Intellibus device is assigned.
3.
Click Discover to update the table of ACUIX dome cameras.
4.
Do one of the following:
Select all of the ACUIX dome cameras, by clicking the checkbox in the Name column. See
figure 6–14.
Select some of the ACUIX dome cameras. If not all of the ACUIX dome cameras are selected,
the cameras are upgraded one by one; see step 9 of this procedure.
5.
Click Firmware Upgrade. A standard, Windows dialog appears, showing the drives and folders
available on the operator's PC.
6.
Select a drive, folder and a firmware file for the ACUIX dome camera. These files should have a
*.ngd file extension.
7.
Click Open.
8.
A Maintenance Message dialog box appears, to confirm the operator's selection. To proceed,
click Yes.
9.
If there are many ACUIX dome cameras connected to the unit, and all were selected in step 4 of
this procedure, a Sequence for Upgrading Cameras dialog box appears. Select a sequence, and
then click Continue. The upgrade of the cameras can be:
Simultaneous. Approximate time: 10 minutes.
One by one. More time consuming; about 10 minutes for each camera.
This upgrade stops if a camera is off, or if the connection fails, and a warning appears for that
camera.
If "Simultaneous" is selected, and an ACUIX dome camera is off, or if the connection fails,
the upgrade appears to continue, without warning the operator. When all of the ACUIX
dome cameras are powered and the connection to them is operational, use this procedure
again.