3. Basic Operation

3.2.6 Checking the Rated Power

On the screen after startup, the rated power icon is displayed in the position shown in Figure 3–5.
The value in the icon indicates the maximum electric power that can be output. In Figure 3–5, the
maximum electric power is 6.0 kVA.
If the rated power is restricted by the power unit energization setting, the icon is highlighted as
shown in Table 3-4. For detailed information about the power unit energization setting, see 4.24.
In some models, the maximum output active power may be restricted when the power supply voltage
is less than or equal to 170 V. In that case, the restricted maximum output active power value is
displayed using the normal icon as shown in Table 3-4. For the restriction applied to the maximum
output active power due to the power supply voltage, see 4.1.5.
定格電力
power icon
アイコン

Table 3-4 How the Rated Power Icon is Displayed Depending on the Power Unit

Normal icon
Example:
Highlighted icon
Example:
-------- Notes----------------------------------------------------------------------------------------------------------------
 For a polyphase model, the total rated power of all phases is displayed.
 For a polyphase system, the rated power is displayed for each phase.
---------------------------------------------------------------------------------------------------------------------------------

3.2.7 Power Off

Disable the output and ensure the OUTPUT LED is off before pressing "Off" side of the power
switch. All screens disappear and all LEDs turn off, then the power input and the output are blocked
inside the system. For a polyphase system, although the order for turning off cabinets is not
significant, a communication error message may appear if the interval between the operations of
turning off the cabinets is too long. This does not cause any problem.
40
Rated

Figure 3-5 The Rated Power Icon

Energization Setting
All power unit energization settings are enabled. The rated power is set to
the maximum value that the model system and the power supply voltage can
provide.
Because some power unit energization settings are disabled, the rated power
is restricted.