10.20 Clipped Sine Wave

The peak clipped sine wave can be output, based on the crest factor (CF) setting or the percent
setting to the peak value.
Number of memories
CF
Variable range
Factory default
Setting resolution
Effective value correction
Clip ratio
Variable range
Factory default
Setting resolution
Effective value correction
Note: The crest factor is represented as "voltage peak value/voltage effective value." It is 1.41 for
sine wave.
Note: When the clip ratio is specified, the peak is clipped by the voltage corresponding to the
specified % to the peak value of the setting voltage (100 %).
Example) For the output voltage setting of 100 Vrms and the clip rate of 80%, the peak is
clipped at 113.1 Vpk.
Note: In the polyphase model, polyphase system, and polyphase output of the Multi-phase model,
these are the settings for the phase voltage.

10.21 Arbitrary Wave

This uses the waveform data saved in the internal memory, which is transferred and recalled using
the external interface or USB memory.
Number of memories
Waveform length
Amplitude resolution
DP Series
10.20 Clipped Sine Wave
All models
3 (non-volatile)
1.10 to 1.41
1.41
0.01
Yes
40.0% to 100.0%
100.0%
0.1%
None
All models
16 (non-volatile)
4096 words
16 bit