Measured Value Display Items; Table 5-3 Measured Value Display Items - NF DP015S Instruction Manual

Dp series programmable ac power source
Hide thumbs Also See for DP015S:
Table of Contents

Advertisement

5. Description of Screen and Menu

5.1.2 Measured Value Display Items

The items displayed inthe measured value area are shown in Table 5-3.
Item
Icon
Represents the phase and type of the measured voltage display.
Output voltage of the single-phase two-wire
Phase voltage of the single-phase three-wire L1 phase
Phase voltage of the single-phase three-wire L2 phase
Line voltage between the single-phase three-wire L1 and L2 phases.
Phase voltage of the three-phase L1 phase
Phase voltage of the three-phase L2 phase
Phase voltage of the three-phase L3 phase
Line voltage between the three-phase L1 and L2 phases
Line voltage between the three-phase L2 and L3 phases
Line voltage between the three-phase L3 and L1 phases
V
Effective value of the output voltage on the output terminal
Vavg
The average DC value of the output voltage on the output terminal
Vmax
Maximum peak value of the output voltage on the output terminal
Vmin
Minimum peak value of the output voltage on the output terminal
SV
Effective value of the voltage on the sensing terminal
SVavg
Average DC value of the voltage on the sensing terminal
SVmax
Maximum peak value of the voltage on the sensing terminal
SVmin
Minimum peak value of the voltage on the sensing terminal
*2
I
Output current effective value
*4
Iavg
Average DC value of the output current
*2
Imax
Maximum peak value of the output current
*2
Imin
Minimum peak value of the output current
*2
Ipk-Hold
Output current peak-hold value
F
Synchronization signal source frequency
*3
P
Output active power
*3
S
Output apparent power
*3
Q
Output reactive power
*4
PF
Power factor of the output power
*4
CF
Output current crest factor
*1: Displays the measured phase voltage value in the Peak display format of the measured value.
Displays the L1 phase voltage in the L1-L2 line voltage display, the L2 phase voltage in the
L2-L3 line voltage display, and the L3 phase voltage in the L3-L1 line voltage display.
*2: Displays the phase current in the phase voltage display for the measured output voltage,the
L1 phase current in the L1-L2 line voltage display, the L2 phase current in the L2-L3 line
voltage display, and the L3 phase current in the L3-L1 line voltage display.
*3: Displays the phase output power in the phase voltage display for the output voltage
measurement, and the all-phase total output power in the line voltage display.
*4: Displays the phase measured value in the phase voltage display for the measured output
voltage. Displays nothing in the line voltage display.
200

Table 5-3 Measured Value Display Items

Description
*1
*1
*1
PROGRAMMABLE AC POWER SOURCE
*1

Hide quick links:

Advertisement

Table of Contents
loading