4. Advanced Operation
4. Supply a DC voltage to the external signal input connector.
5. Turn on the output.
4.18

Control Using External Control Function

You can control the output on/off and the starting/stopping of Sequence by inputting the logic signal
or the non voltage contact signal. You can also get the product state by using the logic signal. The
polarity of state output can be switched. The connector to be used is DBLC-J25SAF-10L9E (D-sub,
25-pin, M2.6 mm screw) manufactured by JAE. For the specification of I/O signals, see 10.26, and
for the pin assignment of the CONTROL I/O connector, see Table 4-12.