10.13 Current Limiter

This controls the output voltage for the output current to be within the limiter setting value when the
peak value or RMS exceeds it. The output can be configured to be turned off when the limited state
continues over the specified time.
In the polyphase model, polyphase system, and polyphase output of the Multi-phase model, the
settings are made for the phase current and common to all the phases.
Peak current limiter
Positive
Setting
Range
current
(Peak
value)
Factory
default
Negative
Setting
Range
current
(Peak
value)
Factory
default
Resolution
Limiter operation
Positive
Setting
Range
current
(Peak
value)
Factory
default
Negative
Setting
Range
current
(Peak
value)
Factory
default
Resolution
Limiter operation
Note: If you increased or decreased the number of units by the power unit energization setting, the
factory default setting corresponding to the capacity is used. (Example: In the case that only
3 units operate in 6 kVA model, the factory default setting of 4.5 kVA model is used.)
DP Series
Single-phase model, Polyphase model, Multi-phase model
015S,030D,045T
030S,060D,090T
045M (polyphase
090M (polyphase
output)
+15.0 A
to
+7.5 A
+63.0 A /
to
+3.7 A
+31.5 A
+7.5 A
+126.0 A /
+63.0 A / +31.5 A
−126.0 A
to
−63.0 A
−7.5 A /
to
−31.5 A
−3.7 A
−63.0 A
−63.0 A / −31.5 A
−126.0 A / −63.0 A
Select whether to recover automatically (continuous, factory default) or
turn the output off when the limited state continues over the specified time
(1 s to 10 s, resolution 1 s).
Single-phase model and Single-phase output of Multi-phase model
075S
to
+37.5 A
+45.0 A
+315.0 A /
to
+18.7 A
+22.5 A
+157.5 A
+315.0 A /
+378.0 A /
+157.5 A
−378.0 A
to
−315.0 A
−37.5 A
/
−189.0 A
to
−157.5 A
−18.7 A
−315.0 A / −157.5 A
−378.0 A / −189.0 A
Select whether to recover automatically (continuous, factory default) or
turn the output off when the limited state continues over the specified time
(1 s to 10 s, resolution 1 s).
045S, 090D
output)
+22.5 A
to
+126.0 A /
+11.2 A
to
+63.0 A
+189.0 A /
+63.0 A
−189.0 A
to
−15.0 A /
−94.5 A
to
−7.5 A
−189.0 A /
0.1 A
090S, 090M
to
+52.5 A
+378.0 A /
to
+26.2 A
+189.0 A
+441.0 A /
+189.0 A
to
−441.0 A
−45.0 A /
to
−220.5 A
−22.5 A
−441.0 A /
0.1 A
10.13 Current Limiter
060S, 120D
to
to
+30.0 A
+189.0 A /
+252.0 A /
to
to
+15.0 A
+94.5 A
+126.0 A
+252.0 A /
+94.5 A
+126.0 A
to
to
−252.0 A
−22.5 A /
−30.0 A /
to
to
−126.0 A
−11.2 A
−15.0 A
−252.0 A /
−94.5 A
−126.0 A
105S
120S
to
to
+60.0 A
+441.0 A /
+504.0 A /
to
to
+30.0 A
+220.5 A
+252.0 A
+504.0 A /
+220.5 A
+252.0 A
to
to
−504.0 A
−52.5 A /
−60.0 A /
to
to
−252.0 A
−26.2 A
−30.0 A
−504.0 A /
−220.5 A
−252.0 A
255