4.2.5 Edit a Sequence

-------- Notes----------------------------------------------------------------------------------------------------------------
 A sequence being edited is kept per AC/DC mode. If AC/DC mode is changed, the edited
contents of sequence are loaded based on the change.
 When the power is turned off, edited contents of the sequence are cleared, and all sequences
have the default setting values when it is started next time. To keep the edited contents of
sequence, save them in the Sequence Memory (see 4.2.8).
 When the sequence is loaded from Sequence Memory, the sequence being edited at that time is
discarded.
---------------------------------------------------------------------------------------------------------------------------------
 Transit to Sequence Edit View
Press the MENU key to open the root menu, then select [Sequence] (see 3.3.1). While the Sequence
Control View is displayed, if you push [Edit] soft-key that is displayed in the output off state, the
execution transitions to the Sequence Edit View.
 Edit a sequence
1. Push [Osc] soft-key on Sequence Edit View, then select AC/DC mode and 100 V/200 V range.
To edit the saved sequence, load the sequence (see 4.2.6).