Font SIMM

1.
Power down the printer. Leave the power cord plugged in to provide
a ground path for static discharges.
2.
Loosen the two rear panel securing screws.
3.
Slide out the main board.
4.
If installed, remove the currently installed font SIMM by spreading
apart the pawls securing each end of the SIMM in its connector.
Remove the SIMM.
5.
Insert a replacement font SIMM in connector FONT (a), and tilt the
SIMM down until it locks in place (b).
When properly inserted, a tab on each end of the connector slips into a
hole on each end of the font SIMM. Also, a pawl on each end of the
connector latches around each end of the SIMM to lock it in place.
Font SIMM

Figure 8-38 Installing the font SIMM on the main board

6.
Reinstall the card cage top and the rear cabinet panels.
7.
Reconnect the host interface cables. Turn on the printer and make a
test print.