System Power-Up Sequence - Tektronix Phaser 360 Service Manual

Color printer
Hide thumbs Also See for Phaser 360:
Table of Contents

Advertisement

Chapter
6

System power-up sequence

Troubleshooting
This chapter discusses troubleshooting the printer. Troubleshooting is discussed
with two approaches:
A step-by-step verification procedure that systematically confirms that
particular components of a printer are properly functioning until a
problem is found.
A symptom/cause scheme that lists particular printer failures and
error codes and their possible causes.
The following lists the chain of events that occur when you turn on a printer.
You can follow this list as one means of determining if the printer is operating
correctly. The exact chain of events depends upon where the printer "believes"
the printhead is positioned. The printer records in NVRAM the last known
position of the printhead and the cap/wipe/purge assembly.
Power switch turned on:
1.
Low-level, power on self test (POST) diagnostics are performed. The
two status LEDs at the rear panel should be blinking.
2.
If POST diagnostics pass, the front panel Power LED turns on and the
rear panel LEDs continue to blink.
3.
Front panel Error LED is turned off and the LCD display is cleared.
4.
If the printhead is in either the Standby or Print position:
a. If the printer is in its Standby mode, the cap/wipe/purge motor is
run to ensure that the cap/wipe/purge assembly activates its
home position sensor. If the printer is in Print mode, the printhead
is moved to its X-axis home-position and then centered.
b. The process motor is rotated to tilt the printhead forward (if not
already forward), rotate all the rollers to their ready positions,
disengage the transfix roller, and lower the maintenance tray blade
and wiper.