Stripper finger assembly
Figure 8-24 Removing the upper and lower stripper finger assemblies
Tools required
Magnetic screwdriver
0.05-inch hex key
3/32-inch hex key
1.
Turn off the printer and remove the power cord.
2.
Remove the top, front panel, right-side and left-side covers as
explained in the topic, "Cabinet panels and covers" on page 8-4.
3.
Disconnect the cables from I/O board 3 and then remove it.
4.
Remove the E-ring securing the exit gear assembly and then remove
the exit gear assembly.
5.
Remove the E-ring securing each end of stripper finger assembly shaft.
Remove the bushings and spring units from the shaft. Remove the
stripper finger assembly.
Stripper finger
assembly
Bushing
Field Replaceable Unit Disassembly/Assembly
T-20 TORX tip
T-15 TORX tip
Small screwdriver or E-ring puller
Transfix roller
Extruded
cam
pin
Bushing
Service Manual
8
Spring
Spring
unit
Spring
unit
9923-54
8-39