Static Did And Two-Way Did - Nortel Modular ICS 6.0 Installer's Manual

Nortel modular ics 6.0 digital system package
Hide thumbs Also See for Modular ICS 6.0:
Table of Contents

Advertisement

set SrvcType to Public
in Services programming access Routing Service to
enter a Destination Code (8 in this example)
set the Absorb Length to All
the telephone that you are dialing out from must have
access to the PRI Pool (programmed in Terminals/Sets)
define rec'd digits for target lines
define limits for incoming and outgoing public calls. Refer
to Programming Call by Call Limits on page 437

Static DID and two-way DID

When configuring static DID with two-way service, the
channels programmed as DID at the CO must be the lowest
B-channels on the PRI. On your Norstar system, the BchanSeq
mode must be set to descending. In this configuration, all
calls on the PRI must be Public service.
For example, channels 1 to 4 are configured as DID at the CO.
The CO uses ascending mode for B-channel selection, and the
ICS uses descending mode.
P0992638 03
Dialing plans / 109
Modular ICS 6.0 Installer Guide