540 / Link Status

Link Status

Fractional PRI

When you purchase PRI from your service provider, you can
request the number of B-channels that are allocated for you to
use. For example, you may want to use only 12 B-channels
instead of 23 B-channels. If this is your situation, you should
disable all the B-channels that you do not need.
It is recommended that the number of lines that are
deprovisioned on a DTI card (configured as PRI) be the same
as the number of B-channels that are disabled. For example
when B-channels 13-23 are disabled, you should deprovision
lines 13 to 23.
Start with the display showing Maintenance
1. Press ≠. System version displays.
2. Press ' until you find Link status.
3. Press ≠. Cards on KSU displays.
4. Press ≠. Cd1-KSU: PRI displays.
5. Press ≠. B channeldisplays.
6. Press ≠. You can view the status of the PRI
channel, for example: PRI:B01 Idle.
Note: When the display shows PRI:B01 Near, it means that
the channel has been disabled by Norstar.
When the display shows PRI:B01 Far, it means that
the channel has been disabled by the CO.
7. Press Enable or Disable key to change the setting for the
channel or press ' to move to the next
B-channel.
Modular ICS 6.0 Installer Guide
P0992638 03