Programming The Pri Routing Table - Nortel Modular ICS 6.0 Installer's Manual

Nortel modular ics 6.0 digital system package
Hide thumbs Also See for Modular ICS 6.0:
Table of Contents

Advertisement

366 / Services
When a PRI protocol is selected or changed, the Service Type
and Service ID fields are automatically cleared for each entry
in the routing table for that PRI.

Programming the PRI routing table

The dialing plan must be thoroughly planned out in advance
before programming the information into the Norstar system.
Programming the routing table takes place in Services under
Routing Service/Routes
1. Press ≠. The display shows Rte000.
2. Press '. The display shows Rte001.
3. Press ≠. The display shows Dial-Out:No
numbr. Press CHANGE to enter a number (up to 24 digits).
4. Press '. The display shows Use: Pool A.
The PRI pool(s) displayed depend on how the PRI lines are
put into pools in the Trunk/Line data section of
programming. It is possible to have only one PRI pool
even if there are two or three PRI cards in the system.
5. Press '. The display shows SrvcType:Public.
Press CHANGE if you want to select a different Service
Type.
Note: This parameter displays for specific protocols,
6. Press '. The display shows Service ID:None.
Press CHANGE to enter the Service ID number. This is
shown only if the service requires an ID.
Note: This parameter displays for specific protocols,
Modular ICS 6.0 Installer Guide
such as N12, DMS100, DMS250.
such as N12, DMS100, DMS250.
P0992638 03