Electrical Requirements - Nortel Modular ICS 6.0 Installer's Manual

Nortel modular ics 6.0 digital system package
Hide thumbs Also See for Modular ICS 6.0:
Table of Contents

Advertisement

184 / Planning the installation

Electrical requirements

non-switched outlet within 1.5 m (5 ft.) of the ICS
å
The ICS and module power cords are 1.5 m (5 ft.) long.
å
You may connect the ICS and modules to a power bar. The
power bar must be CSA certified and UL listed with a
third-wire ground.
Do not use an extension cord between the ICS and the
power bar, or between the power bar and the electrical
outlet.
AC outlet equipped with a third wire safety ground to
å
provide shock protection and avoid electromagnetic
interference
dedicated 110 V AC nominal, 50/60 Hz, 15 A minimum
å
service with a third-wire safety ground
Modular ICS 6.0 Installer Guide
Risk of electric shock.
The safety of this product requires connection to an
outlet with a third-wire ground. Use only with
three-prong power cord and outlet.
Check ground connections.
Ensure that the electrical ground connections of the
power utility, telephone lines and internal metallic water
pipe system, if present, are connected together. If they
are not connected together, contact the appropriate
electrical inspection authority. Do not attempt to make
the connections yourself.