232 / Fiber cable management system

Using the fiber cable management system

To facilitate the installation of an MICS 6.0 or MICS-XC 6.0
configuration, the Fiber Cable Management System ensures
that power cords are located outside of the cable tray. It also
ensures that a 2.6 cm (1 in.) space exists between the ICS
module and other modules.
The following hardware components are used in the Fiber
Cable Management System:
Fiber Comb (one per system): The Fiber Comb, is
installed, using an adhesive back, on the ICS, below the
fiber expansion cartridges. The Fiber Comb keeps the fiber
cable in place and prevents the cables from being pinched
between doors. Use the comb to keep fiber cables
organized as they are routed to each Station Module, as
shown in the 12-port example below.
Fiber Cable Guide (three per system): install in the
entrance and exit of the cable trough. The Fiber Cable
Guide allows fibers to be correctly routed to maintain a
minimum bend radius when going through the cable
trough.
Modular ICS 6.0 Installer Guide
SM14
SM13
SM12
SM11
SM09
SM10
P0992638 03