62 / Working with ISDN
9. Provision the loops and lines , as appropriate, in
Maintenance. Refer to Provisioning BRI and PRI lines on
page 522.
10. If you are configuring auto-answer BRI trunks to map to
target lines, program the received number for the target
line to be the same as the Network DN supplied by your
service provider. This setting is found under Lines.
Assign the ISDN lines and target lines to the appropriate
ISDN DNs, which are the set of DNs reserved for use by
ISDN devices. This setting is found under
Terminals&Sets/Line access. ISDN lines can also be
assigned to the DNs used by the telephones or any other
devices connected to the Modular ICS.
Program the ISDN terminals and devices with the
appropriate ISDN DNs and terminal SPIDs by following
the instructions that come with the devices. For more
information, see Programming ISDN equipment on page
65.
If you are setting up a D-packet service, program the point-
of-sale terminal adapter or other D-packet service device
with the appropriate TEI (provided by your service
provider), terminal SPID, and DN by following the
instructions that come with the device.

Programming ISDN PRI lines

When the configuration programming under Hardware is
complete, your PRI lines are ready to be programmed. For
information on programming your PRI lines, see Call by Call
service selection for PRI on page 433.
Modular ICS 6.0 Installer Guide
P0992638 03