Copying Trunk and Line data

At the Trk/Line data display COPY appears. This allows you
to copy programming from one line to other lines.
Tips -
line, or the other way around, only the data in common is
copied. For example, copying a target line to an E&M trunk
copies only the Line data settings because there are no Trunk
data settings for a target line.
If you try to copy line programming between lines on different
types of Trunk Cartridges, the display shows
Incompatible Cd
cannot copy programming between lines on different types of
Trunk Cartridges.
The Received number of a target line is a unique number and
cannot be copied.

Trunk type

The Line setting shows Loop, DID, PRI, BRI-ST, BRI-U4,
BRI-U2, E&M, Ground or Fixed.
Tips -
that is in use, may cause calls to be dropped.
Tips -
to a DTI. For all other lines, such as analog lines and BRI
lines, the trunk type is determined by the Trunk Cartridge type.
The system simply displays the trunk type; you cannot change
it. To change the Trunk Cartridge or BRI Card, see Hardware
on page 455.
P0992638 03
In copying data from a physical trunk to a target
, then returns to
Changing the settings for a trunk type on a system
You can only change this setting for lines connected
Lines / 335
Show line: _
. You
Installer password required
Modular ICS 6.0 Installer Guide