No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
CTL
Self-diagnostic error: NIB
823
B
[XXXX]: Detailed error code
MAC address check sum error
[6101]
The result of the MAC address check sum does not match the check
sum stored in ROM.
PHY IC error
[6104]
The PHY IC on the controller cannot be correctly recognized.
PHY IC loop-back error
[6105]
An error occurred during the loop-back test for the PHY IC on the
controller.
1.
Replace the controller.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
[1401]
Self-diagnosis error: Standard NVRAM
The controller cannot recognize the standard NVRAM installed or
detects that the NVRAM is defective.
CTL
Loose connection
824
D
Defective standard NVRAM
Defective controller
1.
Check the standard NVRAM is firmly inserted into the socket.
2.
Replace the NVRAM.
3.
Replace the controller