Heating roller fusing lamp overheat 1 (software error)
The detected fusing temperature stays at 230°C for 1 second.
Defective PSU
Defective IOB
543
A
Defective BICU
Related SC code: SC 553
1.
Replace the PSU.
2.
Replace the IOB.
3.
Replace the BICU.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller fusing lamp overheat 1 (hardware error)
During stand-by mode or a print job, the detected heating roller
temperature reaches 250 °C.
Defective PSU
Defective IOB
544
A
Defective BICU
Defective fusing control system
Related SC code: SC 543
1.
Replace the PSU.
2.
Replace the IOB.
3.
Replace the BICU.