1.
Press the "User Tools/Counter" key.
2.
On the touch panel, press "System Settings".
3.
Press "Interface Settings".
4.
Press "IEEE1394".
5.
Press the following soft keys on the touch panel. Then set up the following
settings:
"IP Address": Set the IP Address and Subnet Mask.
"IP over 1394": Enable or disable this setting as required. This setting enables IP
over 1394 as the default setting for the printing method.
"SCSI Print": Enable or disable this setting as required. This setting enables SCSI
Print as the default setting for the printing method.
"Bi-directional SCSI Print": Switch bi-directional printing on or off for SCSI print.
SP Mode Settings for IEEE 1394
The following SP commands can be set for IEEE 1394.
SP No.
Name
5839 007
Cycle Master
5839 008
BCR Mode
IRM 1394a
5839 009
Check
5839 010
Unique ID
5839 011
Logout
5839 012
Login
5839 013
Login MAX
SM
Function
Enables or disables cycle master function of the IEEE
1394 standard bus.
Sets the BCR (Broadcast Channel Register) setting for
the Auto Node operation for the standard IEEE1394
bus for when IRM is not in use. The following three
settings are available: "Standard," "IRM Color Copy,"
and "Always Effective."
Determines whether an IRM check for IEEE 1394a is
conducted for the Auto Node when IRM is not used.
Enables the "Node_Unique_Id" setting for enumeration
on the standard IEEE 1394 bus.
Determines how successive initiator login requests are
handled during login in for SBP-2.
Enables or disables exclusive login for SBP-2.
Sets the limit for the number of logins for SBP-2.
Range: 1 to 62.