3.
Polygon mirror motor cover [B] of the laser optics housing unit (
4.
Polygon mirror motor holder [C] (
5.
Polygon mirror motor [D] (
After installing the laser optics housing unit:
1.
Do the "Forced Line Position Adj. Mode c" (SP2-111-3).
2.
Then do the "Forced Line Position Adj. Mode a" (SP2-111-1).
To check if SP 2-111-1 was successful, watch the screen during the process. A message is
displayed at the end. Also, you can check the result with SP 2-194-10 to -12.