No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller overheat 3 (software error)
The detected fusing roller temperature stays at 230°C or more for 1
second.
Defective PSU
Defective IOB
563
A
Defective BICU
1.
Replace the thermistor.
2.
Replace the PSU.
3.
Replace the IOB.
4.
Replace the BICU.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller overheat 3 (hardware error)
The thermopile detects 250°C or more.
Defective PSU
Defective IOB
Defective BICU
564
A
Defective fusing control system
1.
Replace the thermistor.
2.
Replace the PSU.
3.
Replace the IOB.
4.
Replace the BICU.