Ricoh B230 Service Manual page 299

Hide thumbs Also See for B230:
Table of Contents

Advertisement

No.
Type
-011
-012
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Incorrect dial up connection
-001: Program parameter error
-002: Program execution error
CTL
An unexpected error occurs when the modem (Cumin-M) tries to call
651
C
the center with a dial up connection.
Caused by a software bug
No action required because this SC does not interfere with operation of
the machine.
SM
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Same as -001
1.
Consult with the user's local telephone company.
Incorrect network setting
Both the NIC and Cumin-M are activated at the same time.
Same as -001
1.
Disable the NIC with SP5985-1.
Modem board error
The modem board does not work properly even though the
setting of the modem board is installed with a dial up connection.
Same as -001
1.
Install the modem board.
2.
Check and reset the modem board setting with SP5816.
3.
Replace the modem board.