ΔRH = RH (Relative Humidity) change between the relative humidity of the previous
process control and the current relative humidity
ΔAH = AH (Absolute Humidity) change between the absolute humidity of the previous
process control and the current absolute humidity
1.
Manual execution (forced): This is done when SP3-011-1 is used.
2.
Initial
This starts automatically when the power is turned on, or, when the machine recovers
from energy saver mode.
This is done automatically if one of these conditions occurs.
a) ΔT is greater than or equal to Temperature Threshold (SP3-522-003: 10°C)
b) ΔRH is greater than or equal to Relative Humidity Threshold (SP3-522-004:
50%RH)
c) ΔAH is greater than or equal to Absolute Humidity Threshold (SP3-522-005: 6
3
g/m
)
d) If the following conditions both occur.
BW Counter (SP3-510-003) is greater than or equal to Execution Interval
(SP3-511-005)
OR
FC Counter (SP3-510-004) is greater than or equal to Execution Interval
(SP3-511-006)
Non-use Time is greater than or equal to SP3522-002 (default: 6 hours)
3.
Interval: Job End
This starts automatically at the end of a print job if the following condition occurs:
BW Counter (SP3-510-001) is greater than or equal to Execution Interval
(SP3-515-001)
OR
FC Counter (SP3-510-002) is greater than or equal to Execution Interval
(SP3-515-002)
4.
Interval: During a Job
This interrupts printing and then starts automatically if the following condition occurs:
BW Counter (SP3-510-001) is greater than or equal to Execution Interval
(SP3-515-003)
OR
FC Counter (SP3-510-002) is greater than or equal to Execution Interval
(SP3-515-004)
After process control is completed, the machine continues to make prints.
SM
6-9
B230/B237