(19) Cleaning LPH Assy

NOTE
• After the Imaging Unit has been removed from the main unit, be sure to place it in the
aluminum package or wrap it in a light shielding cloth, and store it in a dark place.
Do not leave the Imaging Unit exposed to light for a extended period of time, as it may
become damaged.
1. Open the Front Door.
2. Slide out the IU (C/M/Y/Bk).
E-22
 
3. Remove the LED Cleaning Jig and LED Cleaning
Jig Pad.
4025E014AA
4. Affix a LED Cleaning Jig Pad to the LED Clean-
ing Jig.
4025E015AA
5. Clean the LED of the LPH Assy by moving the
LED Cleaning Jig three reciprocating motions.
NOTE
• Use only the specified jig (LED Cleaning Jig) for
cleaning.
4025E013AA
E-16