10. Close the Front Door.
11. Place the empty Imaging Unit Cover on the floor.
12. Remove a pair of gloves from the packing box and wear them.
14. Place the Imaging Unit that has been inserted into the Imaging Unit Cover in the alumi-
num pack and place the pack in the packing box.
15. Place the Imaging Unit Pull-out Tray, gloves, and packing material in the packing box.
16. Plug in the power cord.
17. Turn ON the Power Switch.
18. Select "Tech. Rep. Mode"
6. Holding the underside of the Imaging Unit with
your left hand, gently insert the Imaging Unit with
your right hand.
NOTE
• Insert the Imaging Unit until a click is heard.
4025U029AB
7. Remove the Imaging Unit Cover.
8. Check that the Imaging Unit has been inserted all
the way in the copier.
4025U030AB
9. Close the Imaging Unit Locking Lever.
NOTE
• Place the IU Lock Lever into the locked position
until a click is heard.
4025E040AA
13. Insert the old Imaging Unit into the Imaging Unit
Cover.
C4587U024AA
→
"Gradation Adjust" and carry out Gradation Adjust.
E-25