(12) Removal of the LPH Assy

Seal
Flat Cable
8. Remove two screws, unplug one connector, and
remove AIDC/Registration Sensor 2.
4025D075AA
1. Remove the LPH Unit.
D-17
 
2. Remove two screws, unplug one connector, and
remove the Guide Assy.
4025D076AA
3. Remove two screws and, holding the LPH Assy
with hands, unlock it.
NOTES
• Do not touch the LED by hand. Clean the LED, if
touched by hand, using the LED cleaning jig.
• Be careful about the spring that can spring off
when the LPH Assy is unlocked.
4025D077AA
4. Peel off the seal, unlock the LPH Assy, and
remove the flat cable.
5. Unhook the springs.
6. Perform the same procedure for each of different
colors of LPH Assy.
4025D078AB