Minolta CF2002 Service Manual page 147

Hide thumbs Also See for CF2002:
Table of Contents

Advertisement

Item
(Stabilizer Mode)
The image stabilization
sequence is carried out with-
out clearing the historical data
of image stabilization control.
When PRT Max Density,

PRT Highlight, and Back-
ground Voltage Margin of
Tech. Rep. mode are
changed.
(Reset and Stabilizer Mode)
Stabilizer
The image stabilization control
historical data is cleared and
an image stabilization
sequence is carried out.
An abnormal value is

recorded in the historical
data due to a sudden extra-
neous light or other cause.
If any unusual symptom is

noted in gradation and den-
sity even after an image sta-
bilization sequence.
To vary the print start position
in the FD direction for each of
different paper types in the 1st
Drawer.
PRT Area
(Top Margin)
To vary the print start position
in the CD direction for each
paper source.
PRT Area
(Left Margin)
Purpose
When the Start key is pressed, the image
stabilization sequence is carried out with
reference to the historical data.
When the Start key is pressed, the histori-
cal data is cleared and image stabilization
sequence is carried out based on the ini-
tial values.
• Select the appropriate position on the
• Check the test pattern and adjust so

• Select the paper source and press the
• Check the test pattern and adjust so

S-14
Setting/Precautions
paper type setting dial according to the
type of paper loaded in the 1st Drawer
and press the Start key.
that the distance between the leading
edge of the paper and the edge of the
pattern falls within the range of 5 mm
0.5 mm.
The adjustment range is -3.0 mm to
+3.0 mm (in 0.2-mm increments).
Start key.
that the void amount on the left edge of
the paper falls within the range of 3
0.5 mm.
The adjustment range is -3.0 mm to
+3.0 mm (in 0.2-mm increments).
±
±